Output Signal |
Standard 2-wire: 4-20 mA / Vs = 12-28 Vdc
Optional 3-wire: 0.5-5.5 Vdc / Vs = 9-28 Vdc
3-wire: 1-11 Vdc / Vs = 14-28 Vdc
Note: Other output signals available
|
Accuracy |
±0.25% BFSL / ±0.5% for vacuum only |
Temperature Ranges |
Operating: -40°F to 160°F (-40°C to 71°C)
Compensating: 30°F to 160°F (-1°C to 71°C)
Storage: -40°F to 185°F (-40°C to 85°C)
|
Temperature Shift |
0.0125% per °F over compensated range 75°F (24°C) reference |
Vibration |
15 g / 10 to 2,000 Hz (MIL-STD-202) |
Shock |
50 g / 11 ms (MIL-STD-202, M213, Cond. G) |
Pressure Connection |
1/4″ NPTM, 1/2″ NPTM optional |
Housing |
304 SS |
Wetted Parts |
316 SS diaphragm and 17-4PH SS process connection
|
Proof Pressure |
2 x rated pressure or 13,000 psi max |
Current Supply |
3 mA maximum (no load) |
Protection |
EMI, ESD and RFI reverse polarity protected |
Approval |
cULus approved as telemetering equipment for use in hazardous locations
(UL File E146589, WYMV, WYMV7) as follows:
Class I, Div. 1, Groups A, B, C & D
Class II, Div. 1, Groups E, F & G
CRN registered
|
Weight |
7.4 oz. (210 grams): ≤1,000 psi
9.9 oz. (281 grams): ≥2,000 psi
|