Output Signal |
Standard 2-wire: 4-20 mA / Vs = 8-32 Vdc (CSA)
I.S. protection: Vs = 14-28 Vdc
Optional 3-wire: 0-20 mA / Vs = 14-30 Vdc
0-10 V / Vs = 14-30 Vdc
|
Accuracy |
±0.5% FSO IEC 60770 |
Permissible Load |
Current 2-wire: Rmax = [(Vs – Vs min) / 0.02] Ohm
Current 3-wire: Rmax = 500 Ohm
Voltage 3-wire: Rmin = 10 kOhm
|
Influence Effects |
Supply: 0.05% FSO / 10 V
Load: 0.05% FSO / kOhm
|
Response Time |
≤10 ms |
Thermal Error |
≤±0.2% FSO / 10K
In compensated range: -13°F to 185°F (-25°C to 85°C)
|
Permissible Temperatures |
Medium: -40°F to 257°F (-40°C to 125°C)
Electronics environment: -40°F to 185°F (-40°C to 85°C)
Storage: -40°F to 212°F (-40°C to 100°C)
|
Short-circuit Protection |
Permanent |
Reverse Polarity Protection |
No damage. No function. |
Electromagnetic Protection |
Emission and immunity according to EN 61326 |
Stability |
Vibration: 10 g RMS (25 to 2,000 Hz)
Shock: 500 g / 1 ms
|
Pollution Degree |
4, electrical equipment for outdoor use |
Housing |
316L SS |
Pressure Port |
316L SS |
Approval |
CSA Certified for electrical equipment |
Wetted Parts |
Seals: PN < 1,450 psi: FKM70. Others available.
PN > 1,450 psi: FKM90. Others available.
Diaphragm: Ceramic AI2O3 96%
|