- Products
- Mts Sensor
- Mts Sensor MHRM Mobile Hydraulic Position Sensor
Mts Sensor
Mts Sensor MHRM Mobile Hydraulic Position Sensor
Contact with us! 24 business hours (excluding weekends and holidays) to confirm stock status and estimated delivery time.
Output
Signal characteristic Analog output restricted by noise or A/D converter of control unit
Voltage 0.25…4.75 VDC; 0.5…4.5 VDC; 0.25…9.75 VDC; 4.75…0.25 VDC; 4.5…0.5 VDC; 9.75…0.25 VDC
Current 4…20 mA; 20…4 mA
Measured value Position
Measurement parameters
Resolution ±0.1 mm typical
Linearity 0050…0250 mm 0255…2000 mm 2005…2500 mm
? ±0.1 mm ±0.04 % (F.S.) ? ±0.8 mm
Hysteresis ? ±0.2 mm
Setpoint tolerance ±2 mm
Operating conditions
Operating temperature ?40…+105 °C
Storage temperature ?25…+65 °C
Humidity 90 % relative humidity, no condensation
Ingress protection – M12 connector IP67 / IP69K (correctly fitted)
Ingress protection – Sensor housing IP67
Shock test (according to EN 50155) According to EN 61373 Cat2 (Bogie) and Cat3 (Axle)
Vibration test (according to EN 50155) According to IEC 60068-2-64-Fn Cat3 (Axle)
EMC test (according to EN 50155) EN 50121-3-2
ISO 14982 Agricultural and forest machines
EN 13309 Construction machines
ISO 16750-2
Electromagnetic immunity according to EN 61000-6-2
Electromagnetic emission according to EN 61000-6-3
RF immunity 200 V/m per ISO 11452-2/-4
PCB coating According to EN 50155
Pressure (according to DIN EN ISO 19879)* Ø 7 mm sensor rod Ø 10 mm sensor rod
PN (nominal operating) 300 bar 350 bar
Pmax (max. overload) 400 bar 450 bar
Pstatic (proof pressure) 525 bar 625 bar
Design / Material
Housing lid Compound PBT (glass fiber reinforced plastic); sealing ring: TPU
Sealing O-ring NBR with back-up ring PTFE
Sensor electronics housing Stainless steel 1.4305 (AISI 303)
Sensor rod – Ø 7 mm Stainless steel 1.4301 (AISI 304)
Sensor rod – Ø 10 mm Stainless steel 1.4306 (AISI 304L)
Stroke length 50…2500 mm
Mechanical mounting
Mounting instruction Please consult the technical drawings
Mounting position Any
Electrical installation
Connector InterConnection plug
Operating voltage 12 / 24 VDC (8…32 VDC)
24 VDC supply 12 VDC supply
Load (output mA) RL
? 500 ? RL
? 250 ?
Load (output VDC) RL
? 10 k? RL
? 10 k?
Inrush current 4.5 A / 2 ms 2.5 A / 2 ms
Operating voltage ripple 1 %PP
Power drain ? 1 W
Over voltage protection (VDC-GND) Up to +36 VDC
Polarity protection (GND-VDC) Up to ?36 VDC
Insulation resistance R ? 10 M? @ 60 sec according to EN 50155
Dielectric strength 708 VDC (DC ground to machine ground) according to EN 50155
MHRM EMBEDDED – TECHNICAL DATA
*/ According to calculations under use of the FKM guideline
Cycles Ø 7 mm sensor rod Ø 10 mm sensor rod
Dynamic pressure: < 2 × 106
pressure cycles 300 bar 350 bar
Static pressure: < 2 × 104A
pressure cycles 400 bar 450 bar
Proof pressure: Maximum 5 minutes testing time for cylinder pressure test 525 bar 625 bar