Technical DataDosing Drives Series JD
Usable weight up to 22 kg per each drive
Mains voltages 115...230 V, 50/60 Hz optional 42...230 V, 50/60 Hz by Thyristor controller TK5
Switch-on time 100% (operating mode S1)
Protection system IP 65 acc. to EN 60 529
Explosion proof models ATEX available
Paintwork Hammer tone finish pure silver 91
Dosing drives in explosion protected, ATEX execution (JDA/JDE) may only be operated in conjunction with our protective unit "N"
JD drive units are available in four staged sizes, and also in "G" executions for higher effective weights. We would be happy to advise you on special models, such as for higher oscillation amplitudes