- Products
- HEIDENHAIN
- HEIDENHAIN LIDA 409 Exposed Linear Encoder
HEIDENHAIN
HEIDENHAIN LIDA 409 Exposed Linear Encoder
Contact with us! 24 business hours (excluding weekends and holidays) to confirm stock status and estimated delivery time.
Linear scale
LIDA 409
Measuring standard
Coefficient of linear expansion
Steel scale tape with METALLUR scale grating; grating period 20 µm
?therm 10 · 10–6 K–1
Accuracy grade*
±3 µm, ±15 µm1)
Baseline error
? ±0.750 µm/50 mm (typical)
Measuring length ML* in mm
70 120 170 220 270 320 370
420 520 620 720 820 920 1020
Scale tape from the roll: 2 m,4 m, 6 m
Reference marks
One at midpoint of measuring length
Every 50 mm
Mass
31 g/m
Scanning head
LIDA 48
LIDA 47
Interface
1 VPP
? TTL
Integrated interpolation*
Signal period
–
20 µm
5-fold
4 µm
10-fold
2 µm
50-fold
0.4 µm
100-fold
0.2 µm
Cutoff frequency –3 dB
? 400 kHz
–
Scanning frequency*
–
? 400 kHz
? 200 kHz
? 100 kHz
? 50 kHz
? 200 kHz
? 100 kHz
? 50 kHz
? 25 kHz
? 50 kHz
? 25 kHz
? 12.5 kHz
? 25 kHz
? 12.5 kHz
? 6.25 kHz
Edge separation a2)
–
? 0.100 µs
? 0.220 µs
? 0.465 µs
? 0.950 µs
? 0.100 µs
? 0.220 µs
? 0.465 µs
? 0.950 µs
? 0.080 µs
? 0.175 µs
? 0.370 µs
? 0.080 µs
? 0.175 µs
? 0.370 µs
Traversing speed2)
? 600 m/min
? 480 m/min
? 240 m/min
? 120 m/min
? 60 m/min
? 240 m/min
? 120 m/min
? 60 m/min
? 30 m/min
? 60 m/min
? 30 m/min
? 15 m/min
? 30 m/min
? 15 m/min
? 7.5 m/min
Interpolation error
±45 nm
–
Limit switches
L1/L2 with two different magnets; output signals: TTL (without line driver)
Electrical connection
Cable, 0.5 m, 1 m or 3 m with D-sub connector (male) 15-pin
Cable length
See interface description, however limit: ? 20 m (with HEIDENHAIN cable)
Voltage supply
DC 5 V ±0.5 V
Current consumption
< 130 mA
< 150 mA (without load)
Vibration 55 Hz to 2000 Hz
Shock 6 ms
? 500 m/s2 (EN 60 068-2-6)
? 1000 m/s2 (EN 60 068-2-27)
Operating temperature
–10 °C to 70 °C
Mass Scanning head
Connecting cable
Connector
20 g (without cable)
22 g/m
32 g
* Please select when ordering
1) ±5 µm after linear length-error compensation in the evaluation electronics