Scanning head
AK ECA 4410
AK ECA 4410
AK ECA 4490 F
AK ECA 4490 M
AK ECA 4490 P
Interface
EnDat 2.2
Fanuc Serial Interface; ?i Interface
Mitsubishi high speed interface
Panasonic Serial Interface
Ordering designation
EnDat22
Fanuc05
Mit03-4
Pana01
Clock frequency
? 16 MHz
–
Calculation time tcal
? 5 µs
–
Functional safety
For applications up to
SIL 2 according to EN 61 508(further basis for testing: EN 61 800-5-2) Category 3, PL 'd” as per EN ISO 13 849-1:2015
–
PFH
? 20 · 10–9
(up to 6000 m above sea level)
–
Electrical connection
Cable, 1 m or 3 m with 8-pin M12 coupling (male) or 15-pin D-sub connector
Cable length1)
? 100 m
? 50 m
? 30 m
? 50 m
Voltage supply
DC 3.6 V to 14 V
Power consumption (max.)
At 3.6 V: 700 mW
At 14 V: 800 mW
At 3.6 V: 850 mW
At 14 V: 950 mW
Current consumption (typical)
At 5 V: 90 mA
(without load)
At 5 V: 100 mA
(without load)
Vibration 55 to 2000 Hz
Shock 6 ms
? 200 m/s2 (EN 60 068-2-6)
? 200 m/s2 (EN 60 068-2-27)
? 500 m/s² (EN 60 068-2-6)
? 1000 m/s² (EN 60 068-2-27)
Operating temperature
–10 °C to 70 °C2)
–10 °C to 70 °C
Protection EN 60 5293)
IP67
Mass Scanning head
Connecting cable
Coupling (M12)
18 g (without cable)
20 g/m
15 g
1) With HEIDENHAIN cable; clock frequency ? 8 MHz
2) With drum outside diameter of 104.63 mm: 10 °C to 70 °C
3) In the application the device must be protected from contamination by solids and liquids. If necessary, use a suitable enclosure with seal and sealing air
Scale drum
TTR ECA 4400 scale drum
Measuring standard
Coefficient of expansion
Steel drum
?therm ? 10.4 · 10–6 K–1
Drum inside diameter*
70 mm
80 mm
120 mm
120 mm
150 mm
180 mm
270 mm
425 mm
512 mm
Drum outside diameter*
104.63
mm
127.64 mm
148.2
mm
178.55 mm
208.89 mm
254.93 mm
331.31
mm
484.07 mm
560.46 mm
Safe position1) 2)
±0.88°
±0.44°
±0.22°
±0.11°
Safety-related measuring step SM
0.352°
(10 bits)
0.176°
(11 bits)
0.088°
(12 bits)
0.044°
(13 bits)
Mech. permissible speed
? 8500
rpm
? 6250 rpm
? 5250 rpm
? 4500 rpm
? 4250 rpm
? 3250 rpm
? 2500 rpm
? 1800 rpm
? 1500 rpm
Max. angular acceleration
14 000
rad/s2
6600
rad/s2
7900
rad/s2
2700
rad/s2
1800
rad/s2
1000
rad/s2
1300
rad/s2
900
rad/s2
1200
rad/s2
Elec. permissible speed
? 7000 rpm
? 5750 rpm
? 4400 rpm
? 3000 rpm
? 2550 rpm
? 2100 rpm
? 900 rpm
? 600 rpm
? 550 rpm
Moment of inertia
0.81 · 10-3 kgm2
1.9 · 10-3 kgm2
2.3 · 10-3 kgm2
7.1 · 10-3 kgm2
12 · 10-3 kgm2
28 · 10-3 kgm2
59 · 10-3 kgm2
195 · 10-3 kgm2
258 · 10-3 kgm2
Permissible axial movement
? ±0.4 mm (scale drum relative to the scanning head)
Positions per revolution
134 217 728 (27 bits)
268 435 456 (28 bits)
536 870 912 (29 bits)
Measuring step
0.0097'
0.0048'
0.0024'
Signal periods
8195
10 010
11 616
14 003
16 379
19 998
25 993
37 994
44 000
Accuracy of graduation
±3.7”
±3.0”
±2.8”
±2.5”
±2.5”
±2.5”
±2.5”
±2.0”
±2.0”
Interpolation error per signal period
RMS(1?)
±0.20'
0.040'
±0.16'
0.032'
±0.14'
0.028'
±0.12'
0.023'
±0.10'
0.020'
±0.08'
0.016'
±0.06'
0.012'
±0.04'
0.009'
±0.04'
0.007'
Protection EN 60 5293)
Complete encoder in mounted condition: IP00
Mass
? 0.40 kg
? 0.68 kg
? 0.51 kg
? 1.2 kg
? 1.5 kg
? 2.3 kg
? 2.6 kg
? 3.8 kg
? 3.6 kg
* Please select when ordering
1) Further tolerances may occur in subsequent electronics after position value comparison (contact manufacturer of subsequent electronics)
2) Mechanical connection: fault exclusions for loosening of the scanning head and scale drum (page 36)
3) In the application the device must be protected from contamination by solids and liquids. If necessary, use a suitable enclosure with seal and sealing air
Scale drum
TTR ECA 4402 (ECA 4402 scale drum)
Measuring standard
Coefficient of expansion
Steel drum
?therm ? 10.4 · 10–6 K–1
Drum inside diameter*
70 mm
80 mm
120 mm/
150 mm
130 mm
150 mm/
185 mm
180 mm/
210 mm
270 mm
425 mm
512 mm
Drum outside diameter*
104.63 mm
127.64 mm
178.55 mm
148.20 mm
208.89 mm
254.93 mm
331.31 mm
484.07 mm
560.46 mm
Mech. permissible speed
? 8500 rpm
? 6250 rpm
? 4500 rpm
? 5250 rpm
? 4250 rpm
? 3250 rpm
? 2500 rpm
? 1800 rpm
? 1500 rpm
Electrically permissible speed
? 7000 rpm
? 5750 rpm
? 3000 rpm
? 4400 rpm
? 2550 rpm
? 2100 rpm
? 900 rpm
? 600 rpm
? 550 rpm
Moment of inertia
0.83 · 10-3 kgm2
2.0 · 10-3 kgm2
7.1/
4.5 · 10–3
kgm2
1.7 · 10–3
kgm2
12/
6.5 · 10–3
kgm2
28/
20 · 10–3
kgm2
59 · 10–3
kgm2
199 · 10-3 kgm2
263 · 10-3 kgm2
Permissible axial movement
? ±0.4 mm (scale drum relative to the scanning head)
Positions per revolution
134 217 728 (27 bits)
268 435 456 (28 bits)
536 870 912 (29 bits)
Measuring step
0.0097'
0.0048'
0.0024'
Signal periods
8195
10 010
14 003
11 616
16 379
19 998
25 993
37 994
44 000
Accuracy of graduation
±3”
±2.5”
±2”
±2.3”
±1.9”
±1.8”
±1.7”
±1.5”
±1.5”
Interpolation error per signal period
RMS (1s)
±0.20'
0.040'
±0.16'
0.032'
±0.12'
0.023'
±0.14'
0.028'
±0.10'
0.020'
±0.08'
0.016'
±0.06'
0.012'
±0.04'
0.009'
±0.04'
0.007'
Protection EN 60 5291)
Complete encoder in mounted condition: IP00
Mass
Scale drum
? 0.42 kg
? 0.69 kg
? 1.2 kg/
0.66 kg
? 0.35 kg
? 1.5 kg/
0.66 kg
? 2.3 kg/
1.5 kg
? 2.6 kg
? 3.8 kg
? 3.7 kg
* Please select when ordering
1) In the application the device must be protected from contamination by solids and liquids. If necessary, use a suitable enclosure with seal and sealing air