ESN
ESN Type 8531 Cable Monitoring Device
Contact with us! 24 business hours (excluding weekends and holidays) to confirm stock status and estimated delivery time.
The cable monitoring device type 8531 is suitable for insulation monitoring of cable systems used for traction current supply of direct current railways and trolley busses with nominal voltages of up to 750 V.
Technical Data
Dimensions
W/H/D, s. fig., 150 / 200 / 75 mm
Housing
Protection system
IP 50
Material
Macrolon
Ambient temp.
-20°C to +50°C
Traction voltage
DC 600 V / 750 V +20% / -30%
Power consumption
approx. 8 W
Shield voltage (nominal value at 750 V)
approx. 40 V at DC 750V (corre- sponds to 68 k of test resistance and 1.12 M of series resistance)
Switching points
insulation limit value adjustable
Insulation ”shield-earth”
50 - 300 k?
Insulation ”conductor-
350 – 1,500 k?
shield”
Outputs
1 relay for voltage fault (quiescent current operation)
1 relay, fault ”shield-earth”
1 relay, fault ”conductor-shield”
Contacts
2 changeover contacts each (potenti-
al-free)
Voltage Current
AC 250 V 4.0 A
DC 60 V 0.5 A
ON delay
approx. 2.5 s
Switch-in delay
fault to earth: approx. 20 s internal fault: approx. 2 s
Versions
Without display shield interruption
? 8531 00
With display shield interruption
? 8531 10
(as display short ”conductor-shield”)
With display shield interruption
? 8531 20
(as display short ”shield-earth”)
Accesoirs
Terminating resistor see brochure sheet type 853196; Testing unit for
adjusting and testing purposes see
brochure sheet type 853299
Ordering Information
Type
Order No.
8531 00
510100
8531 10
510101
8531 20
510102