CALYS 50 is a basic multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field and lab measurements, it can simultaneously measure and generate over two isolated channels various signals of temperature, resistance, process and frequency in one single instrument.
It provides extended functionalities (temperature simulation, scaling, steps, synthesizer, statistical functions…), easily accessible through quick menus by function.
The instrument simultaneously measures and simulates:
Temperature: Up to 0,014% RDGResistance: Up to 0,012% RDG, 4 K? rangeCurrent: Up to 0,0175% RDG, 50 mA range + 24 V loop supplyVoltage: Up to 0,013% RDG, 50 V IN / 20 V OUT rangeFrequency: Up to 0,005% RDG, 20 KHz range (10 KHz in simulation)IP 54, fully protected by an antichoc rubber holster, CALYS 50 integrates "easyconnect" terminals and a wide backlite display that makes it easy to use in any severe or dark conditions.
Easy connection systemConnect your probes by simply pushing on the terminal top and insert wires of up to 3 mm or 10 AWG diameter and compensated thermocouple connectors.
Wires are held tight between two brass plates ensuring thermal stability and a very good cold junction compensation for thermocouples.
This system also enables 4 mm banana plugs and security connectors to be connected on the terminal top.
Specifications
CALYS 50
CALYS 75
CALYS 100
CALYS 150
Top accuracy
200 ppm
130 ppm
50 ppm
Temperature accuracy
Thermocouples (14)
RTDs (12)
0.013% RDG for Tc K
0.012% RDG
0.01% RDG for Tc K
0.01% RDG
0.005% RDG for Tc K
0.006% RDG
DC current
+ Loop supply 24 V
Range
Accuracy
50 mA
0.0175% RDG
100 mA
0.007% RDG
DC voltage
Range
Accuracy
50 V IN / 20 V OUT
0.013% RDG
50 V
0.010% RDG
50 V
0.005% RDG
Frequency
Range
Accuracy
20 KHz IN / 10 KHz OUT
0.005% RDG
100 KHz
0.01% RDG
Resistance
Range
Accuracy
4000 ?
0.012% RDG
4000 ?
0.010% RDG
50 K?
0.006% RDG
Pressure
Range
Accuracy
Relative pressure: 30 bar / Absolute
pressure: 1,000 bar
0.05% RDG
Compliance to standards
21 CFR Part 11
NADCAP Heat treatment AMS 2750
Additional functions
Advanced data exploitation: Scaling,
relative measurement, simulation of ramps and steps, synthetizer, square
root, statistical functions
Transmitter function
Additional functions
Switch test
Calibration of transmitters
Additional functions
Comparison calibration
HART: Digital calibration and data transfer
Calibration of thermistors
Software
DATACAL calibration software for configuration and data management
Memory
10,000 data stored and recalled on screen as curve or list